HDS ViewStation System Administrator's Guide

A Hypertext Document


Installing HDS Video Software

This page describes installling the ViewStation's HDS Video software.

Installing HDSware netVideo Software
Installing HDSware 3.1.0.1 netVideo software
If you have HDSware 3.1.0.1 or higher, you can use the installation script to install the video software. If your site has some video ViewStations and some regular ViewStations, you can install the HDSware 3.1.0.1 with the video options and use that software for all units. The HDS netVideo clients will appear on the HDSperx menu of all ViewStations, but the video clients won't start on non-video ViewStations.

If you have customized your configuration files (config.fx and clients.config), you should copy them to another directory and then restore the customized lines to the new configuration files after your installation is complete.

1. Load the HDSware tape on your system (use the HDSware Installation Guide for sample tape commands) and get the installation script.

For example:
tar xvf <device name> HDSvidinstall

This finds the installation script; it is the first file on the tape. The tar command continues to search through the entire tape, which may take a few minutes. Once the screen reports that the HDSvidinstall is loaded, you can discontinue the search by typing Ctrl-C.

2. Run the installation script by typing:
HDSvidinstall

3. HDSvidinstall requests two things:
-- the path of your HDSware directory
-- the device name of your tape drive

4. HDSvidinstall will check for the presence of the ./hds-fx directory to determine if your HDSware path is correctly specified. It will also check to see that the files in the directory /hds-fx/hdsvideo are writable, and exits if they are not. Verify that the write permissions are correct.

The installation proceeds and notifies you when complete. You need to reboot your ViewStation in order to use the video software.

Installing HDSware Video Software with Version 3.1
You must have HDSware 3.1 server software installed in order to use the HDSware video software.

If you have customized your configuration files (config.fx and clients.config), you should copy them to another directory and then restore the customized lines to the new configuration files after your installation is complete.

1. Load the HDSware video software tape on your system. You should change your directory to the HDSware directory - /path/hds-fx and load the tape into that directory.

For example:
cd /<path>/hds-fx tar xvf<device name>

The tar command should load the /hdsvideo directory into the hds-fx tree. You can delete the HDSvidinstall script if you wish.

2. Edit the /hds-fx/config/clients.config file with a text editor (make sure you have the file permission to do this).

3. Remove the comment character from the hds.server.Extensions line for the MIT-SHM extension. This is available with HDSware 3.1.
hds.serverExtensions: /FXUtilities/hds-fx/extensions/MIT-SHM

4. Add this line at the end of the file:
#include "../hdsvideo/config/hdsvideo.clients"

5. Save the clients.config file.

You need to reboot your ViewStation in order to use the video software. The clients.config file points to the new HDSware video clients and they will appear on your HDSperx menu in your window manager's root menu.

Return to Section Heading Page


Return to the Home Page

If you need more information than is available here, you can reach HDS via email at info@hds.com, or call us at 1.800.HDS.1551 in the USA, or at +610.277.8300 from outside the US. For questions or problems regarding the HDS WWW page, contact webmaster@hds.com.