This page describes selecting the monitor type
for the ViewStation.
The following table shows monitors
currently supported by HDS. Monochrome and grey-scale monitors
typically differ only in the amount of VRAM present.
Note that the sync frequency varies with the resolution (which
is user-selectable) of the monitor; the values below are the HDS
factory setting. Some multi-sync monitors have a frequency shown which
is the HDS factory specification appropriate for optimum display
characteristics. A * indicates that a jumper is needed.
The ViewStation produces video signals with separate sync
signals or composite sync on green. Selecting JP12 3-4 on the
ViewStation FX (JP 13 on the LX series, and JP13 on the Ultra series)
turns off the sync on green signal (hex switch 5 video automatically
shuts off sync on green).
The ViewStation uses negative polarity for its video signals.
You can select positive polarity with jumpers on the main board in JP9
for the ViewStation FX (JP12 for the LX series, and JP 11 for the Ultra
series), which is located near the round hex switch. To select positive
polarity:
HSYNC - install jumper 1-2
VSYNC - install jumper
3-4
All monochrome monitors select grey-scale operation
automatically, except the MO-V14R, which requires JP13 5-6.
Return to Section Heading Page
Return to the Home Page
If you need more information than is available here, you can reach
HDS via email at info@hds.com, or
call us at 1.800.HDS.1551 in the USA, or at +610.277.8300 from outside
the US. For questions or problems regarding the HDS WWW page, contact
webmaster@hds.com.
© 1996 by HDS Network Systems
Inc.